9.2.6

Logging

9.2.6.1
Configuring Buffered Log
This log stores messages in memory based upon the settings for message component and severity. On
stackable systems, this log exists only on the top of stack platform. Other platforms in the stack forward
their messages to the top of stack log.
Figure : Buffered Log Config
Configurable Data
Admin Status - A log that is "Disabled" shall not log messages. A log that is "Enabled" shall log
messages. Enable or Disable logging by selecting the corresponding line on the pull down entry
field.
Behavior Indicates the behavior of the log when it is full. It can either wrap around or stop when the
log space is filled.
Command Buttons
Apply - Update the switch with the values you entered.