Inform Retries - Specify how many times to resend the inform. The valid retry value is 0 to 100.
Default retry value is 3 times.
Inform Timeout - Specify how many seconds does the switch to wait for the inform ACK. If the
inform ACK is not received within the configured timeout value, switch will resend the infrom
according to the retry setting. The valid timeout value is 0 to 1000 seconds. Default timeout value is
15 seconds.
SNMP Community Name/SNMP User - Enter the community string or SNMP user for the SNMP
inform packet to be sent to the trap manager. This may be up to 16 characters and is case sensitive.
IP Address - Enter the IP address to receive SNMP inform from this device. Enter 4 numbers
between 0 and 255 separated by periods.
Command Buttons
Apply - Update the switch with the values on this screen. If you want the switch to retain the new
values across a power cycle, you must perform a save.
Delete - Delete the currently selected Community Name. If you want the switch to retain the new
values across a power cycle, you must perform a save.