10.6.18.6
sflow sampler
A data source configured to collect flow samples is called a poller. Use this command to configure a new
sFlow sampler instance for this data source if <rcvr_idx> is valid.
Syntax
sflow sampler {<rcvr-indx> | rate <sampling-rate> | maxheadersize <size>}
no sflow sampler [rate | maxheadersize]
<rcvr_idx> - The sFlow Receiver for this sFlow sampler to which flow samples are to be sent. A value
of zero (0) means that no receiver is configured, no packets will be sampled. Only active receivers can
be set. If a receiver expires, then all samplers associated with the receiver will also expire. Possible
values are 1-8. The default is 0.
<size> - The maximum number of bytes that should be copied from the sampler packet. The range is
20-256. The default is 128. When set to zero (0), all the sampler parameters are set to their
corresponding default value.
<sampling-rate> - The statistical sampling rate for packet sampling from this source. A sampling rate
of 1 counts all packets. A value of zero (0) disables sampling. A value of N means that out of N
incoming packets, 1 packet will be sampled. The range is 1024-65536 and 0. The default is 0.
no - Use this command to reset the sFlow sampler instance to the default settings.