Fujitsu PRIMERGY BX900 User Manual page 180

Blade server systems ethernet connection blade module sb6 / sb11a / sb11 switch version
Hide thumbs Also See for PRIMERGY BX900:
Table of Contents

Advertisement

9.2.16.3
Poller Config
sFlow agent collects time-based sampling of network interface statistics and sends them to the
configured sFlow receivers. A data source configured to collect counter samples is called a poller.
Figure : sFlow Poller Config
Selection Criteria
Interface - sFlowDataSource for this sFlow poller. This Agent will support Physical ports only.
Configurable Data
Receiver Index - The sFlowReceiver associated with this counter poller. Allowed range is (1 to 8 ).
Poller Interval - The maximum number of seconds between successive samples of the counters
associated with this data source. A sampling interval of 0 disables counter sampling. Allowed range
is (0 to 86400 secs).
Non-Configurable Data
Receiver Index - The sFlowReceiver for this sFlow Counter Poller. Only active receivers can be set.
If a receiver expires then all pollers associated with the receiver will also expire. Allowed range is (1
to 8 )
Poller Interval - The maximum number of seconds between successive samples of the counters
associated with this data source.
Command Buttons
Apply - Send the updated data to the switch and cause the changes to take effect on the switch.
Delete - Delete the poller data.
Refresh - Refresh the data on the screen with present state of data in the switch.