9.4.7.3
IP Rule Config
Use these screens to configure the rules for the IP Access Control Lists created using the IP Access
Control List Configuration screen. What is shown on this screen varies depending on the current step in
the rule configuration process. A Standard/Extended IP/Name ACL must first be selected to configure
rules for. The rule identification, and the 'Action' and 'Match Every' parameters must be specified next. If
'Match Every' is set to false a new screen will then be presented from which the match criteria can be
configured.
Figure : Access Control Lists IP Rule Config
Selection Criteria
IP ACL - Use the pull down menu to select the IP ACL for which to create or update a rule.
Rule - Select an existing rule from the pull down menu, or select 'Create New Rule.' ACL as well as
an option to add a new Rule. New rules cannot be created if the maximum number of rules has been
reached. For each rule, a packet must match all the specified criteria in order to be true against that
rule and for the specified rule action (Permit/Deny) to take place.
Configurable Data
Rule ID - Enter a whole number in the range of 1 to 10 that will be used to identify the rule. An IP
ACL may have up to 10 rules.
Action - Specify what action should be taken if a packet matches the rule's criteria. The choices are
permit or deny.
Logging - When set to 'True', logging is enabled for this ACL rule (subject to resource availability in
the device). If the Access List Trap Flag is also enabled, this will cause periodic traps to be
generated indicating the number of times this rule was 'hit' during the current report interval. A fixed 5
minute report interval is used for the entire system. A trap is not issued if the ACL rule hit count is
zero for the current interval. This field is visible for a 'Deny' Action.
Assign Queue ID - Specifies the hardware egress queue identifier used to handle all packets
matching this IP ACL rule. Valid range of Queue Ids is (0 to 7). This field is visible for a 'Permit'
Action.