10.6.5.14
snmp-server inform timeout
This command set how many seconds does the switch to wait for the inform acknowledgement.
Syntax
snmp-server inform timeout
no snmp-server inform timeout
no - This command restore the default setting of snmp inform timeout value.
Default Setting
15 seconds.
Command Mode
Global Config
10.6.5.15
snmp-server user
This command create a snmp user for SNMPv3.
Syntax
snmp-server user <username> auth <md5 | noauth | sha> <0-7> <pass> priv <des> <0-7> <pass>
no snmp-server user <username>
<username> - user name.
<md5 | noauth | sha> - authentication method.
<pass> - password.
<des> - encryption method.
no - This command delete an snmp user.
Command Mode
Global Config