Audit Code; Adding The Audit Code - OSI Security Devices OMNILOCK OM100 Series User Manual

Omnilock access control systems
Hide thumbs Also See for OMNILOCK OM100 Series:
Table of Contents

Advertisement

Programming in Menu Mode
If you want to change the Time Limit, select 6-TIME LIMIT from the
Service Code Menu:
-- SERVICE CODE MENU ---
)
1-ADD 2-REMOVE 3-VERIFY
4-HOLD 5-RESTORE
6-TIME LIMIT (01:00)
If you select 6-TIME LIMIT, the following prompt will print:
SVC CODE TIME (hhmm)?
Enter the new Service code time limit as hhmm, where hh is hours in the
range 00 - 99 and mm is minutes in the range 01 - 59. (You must add a
leading 0 for hours and minutes less than 9, e.g., 0507). The System ships
from the factory with the Service Code Time set to one hour (0100).
Note
Setting the Service code time to 00:00 provides a
'One-time' use code.
Setting the Service code time to 99:99 will allow the
Service code to remain valid indefinitely.
Once you have entered a new Service Code Time Limit, the Service Code
Menu will reprint. You can then verify the change by observing the new
time limit displayed.

Audit Code

Adding the Audit Code

Programming Code Required:
Master Code, or
Submaster Code with menu privilege 2-CODES
60

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omnilock om300 seriesOmnilock om500 series