The Open Delay Time controls the length of time the System remains
unlocked after a valid code is entered. As shipped from the factory and
when the System is reset, this time is two seconds. (See Resetting The
System page 118.)
You can set a delay time from 1 to 30 seconds.
Note
Increasing the Open Delay Time can significantly
reduce battery life.
To set the Open Delay Time, while in Menu Mode, press 5-SETUP from the
Main Menu:
------ MAIN MENU ------
)
1-AUDIT 2-CODES 3-ACCESS
4-SCHEDULE 5-SETUP 0-END
Next, select 3-DEFAULTS from the Setup Menu:
)
------ SETUP MENU ------
1-STATUS REPORT 2-CLOCK
3-DEFAULTS 4-AUTOCODES
5-RUN DIAGNOSTICS
Then, select 1-OPEN DELAY SECONDS from the Defaults Menu:
)
---- DEFAULTS MENU -----
1-OPEN DELAY SECONDS: 02
2-DAYLIGHT: NORTHERN
3-GROUP BOUNDARIES
4-LOCATION: 123456
The following prompt will print:
OPEN DELAY SECONDS (##)?
Programming in Menu Mode
97