OSI Security Devices OMNILOCK OM100 Series Installation Instructions Manual

Omnilock access control systems non-weatherized, mortise locksets using falcon lm series locks (lever)
Hide thumbs Also See for OMNILOCK OM100 Series:

Advertisement

D EVIC E S
INSTALLATION INSTRUCTIONS
AND OM500 SERIES
LOCKSETS USING
WARNING: THIS PRODUCT IS NOT WARRANTED FOR
OUTDOORS USE!
NOTE: A DOOR-CLOSER IS HIGHLY RECOMMENDED
FOR USE WITH THIS PRODUCT.
THIS PRODUCT IS NORMALLY FACTORY-PACKED
FOR RIGHT-HAND 1-3/4" TO 2" THICK DOORS.
TO CHANGE HAND OF LOCK, SEE
INSTRUCTION SECTION 2.
RIGHT HAND SHOWN
DOOR HANDLING
LEFT
INSIDE
HAND
OUTSIDE
INSIDE
LEFT HAND
REVERSE
OUTSIDE
BEVEL
DOOR HAND DETERMINED FROM OUTSIDE
TERMINAL BLOCK
CPU PC
(FOR REMOTE SWITCH)
BOARD
ASSEMBLY
MOTOR
CONNECTOR
WASHER
SCREW, PAN HEAD TORX
#8-32X1-1/2" FOR 2" THICK DOOR
#8-32X1-1/4" FOR 1-3/4" THICK
DOOR (2-REQD)
THUMB TURN
SCREW, FLAT
HEAD #6X1/2"
(2-REQD)
SET
COLLAR
SCREW
INSIDE
LEVER
SCREW, FLAT
HEAD #10-32 X 2"
WASHER
(2 REQD)
SECURITY
NON-WEATHERIZED,
FALCON
RIGHT
HAND
SEMS #4-40X1/4"
PAN HEAD
RIGHT HAND
REVERSE
STANDOFF
BEVEL
#8-32X1"
(2-REQD)
RESET
BUTTON
RED
WIRE
GASKET
BLACK
WIRE
CONNECTOR
(Routes through
the slot in the
NYLON
SPINDLE & SPRING
ASSEMBLY
INNER INSERT
ASSEMBLY
SCREW
FLAT HEAD
#12 X 1" (2-REQD)
OMNILOCK
ACCESS CONTROL SYSTEMS
FOR OM100, OM300,
LM SERIES LOCKS (LEVER)
INTERCHANGEABLE CORE (I.C.)
I.C. CORE
(NOT SUPPLIED)
I.C. CYLINDER
WITH CAM
HOUSING
ASSEMBLY
AA ALKALINE
BATTERY, 1.5V
(4-REQD)
BATTERY
COVER
BACK
PLATE
SCREWS,
FLAT HEAD
#8-32X3/8"
LG (2-REQD)
LOCK
SPINDLE & SPRING
Door)
ASSEMBLY
LOCK
FACE
PLATE
MORTISE
CONTROL KEY
(NOT SUPPLIED)
CYLINDER
COLLAR
ELECTRONICS MODULE
CONNECTOR
SCREW
PAN HEAD
#6-32X1/4"
GROUND
OUTER TRIM
SPRING
ASSEMBLY
SCREW
POST
SCREW
FLAT HEAD
#8X2-1/4"
(2-REQD)
SCREW
FLAT HEAD
#12 X 1"
(2-REQD)
STRIKE
STRIKE
BOX
KEY
WAVY
WASHER
CYLINDER
WITH CAM
PG. 1 OF 8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OMNILOCK OM100 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for OSI Security Devices OMNILOCK OM100 Series

  • Page 1  SECURITY OMNILOCK D EVIC E S ACCESS CONTROL SYSTEMS INSTALLATION INSTRUCTIONS FOR OM100, OM300, NON-WEATHERIZED, AND OM500 SERIES MORTISE ™ FALCON LOCKSETS USING LM SERIES LOCKS (LEVER) WARNING: THIS PRODUCT IS NOT WARRANTED FOR INTERCHANGEABLE CORE (I.C.) OUTDOORS USE! NOTE: A DOOR-CLOSER IS HIGHLY RECOMMENDED I.C.
  • Page 2 SECTION 1: CHECK OPERATION a. Connect the Lock Connector to the Electronics Module Connector so that the Red Wires are aligned. Refer to Fig.1. b. Verify proper operation of the System by entering the Default Master Code 5 0 1 1 2 3 4 . The System will flash three times to indicate the Battery level and unlock.
  • Page 3 LOCK ASSEMBLY FACE PLATE “T” TURN CYLINDER RETRACT LEVER LATCH BOLT SPRING DEAD BOLT FOOT DEAD LOCKING UPPER RETRACT BLOCKER ASSEMBLY COUPLING LOCK FRONT SCREW FIG.2 PG. 3 OF 8...
  • Page 4 a. Holding the Lever as shown, bend the Tab of the Lock REVERSE HANDLE RETURN SPRING Washer back flat. Remove the Nut. Example shown is a right hand being changed to a left hand. Reverse the sequence to change from a left hand to a right hand.
  • Page 5 SECTION 3: PREPARE THE DOOR a. Draw a horizontal centerline on both sides and edge of the Door at the desired Knob Center Height Refer to Fig. 3. NOTE: If the Frame has already been prepared for a Falcon Strike, LOCATING POSITION OF install the Strike and use the Strike Lip as a reference to locate the HORIZONTAL CENTERLINE...
  • Page 6 SECTION 4: INSTALL THE LOCK a. Remove the Face Plate and guide the Connector and the Lock into Mortise so that the Cable passes through the slot above the Cylinder hole and the Lock is seated in the Mortise. Refer to Fig.9. CAUTION: Do not pinch the Cable.
  • Page 7 INSTALL THE ELECTRONICS MODULE MOUNTING SCREW (2 REQD) a. Guide the Connectors through the front hole in the Module, and place the Module against the Door so that the Standoffs and the Grounding Spring enter their respective holes. Refer to Fig.11. b.
  • Page 8 INSTALLER NOTES: Leave these instructions and other Documents with the User. Copyright 2001 OSI Security Devices Inc. All Rights Reserved OMNILOCK is a Registered Trademark of OSI Security Devices Inc. FALCON is a trademark of Falcon Lock Co. 11523 Rev A 1580 JAYKEN WAY (Website: WWW.OMNILOCK.COM)

This manual is also suitable for:

Omnilock om500 seriesOmnilock om300 series

Table of Contents