Programming in Command Mode

Access Level

Programming Code Required:
Master Code, or
Submaster Code with menu privilege 3-ACCESS
To set the access level of the System, enter the following command
sequence while in the Command mode:
where Level is the Access level to set: 1-Unlocked, 2-Code Required, 3-
Lockout or 4-Shutdown. (4-Shutdown is only programmable with the
Master code)
To indicate the Access Level, the lights will flash as follows:
Green
Green-Green
Green-Green-Green
Green-Green-Green-Green
Red-Red

Enable Groups

Programming Code Required:
Master Code, or
Submaster Code with menu privilege 3-ACCESS
With the Enable Groups command, you can re-enable a previously disabled
user group (or groups). This command may also be used to set a group's
level of supervision to supervised or unsupervised in the absence of a
Supervisor code. For example, if the supervisor of a work group is out ill,
then you can use this command to allow access to the workers within the
affected Group.
26
90 + Level + CL
Level 1: Lockset is unlocked.
To set Level 1 to unlock with first code,
continue to hold the CL key until a second
green flash appears, (about. 1.5 seconds).
Level 2: Code required
Level 3: Lockout
Level 4: Shutdown
Invalid Access Level