Programming in Menu Mode
Running Diagnostics
Programming Code Required:
Master Code, or
Submaster Code with menu privilege 5-SETUP
The Diagnostic Report provides information about the mechanical and
electrical condition of the system. It may be used as a trouble shooting aid.
The Diagnostic function does not report on the condition of theWall Mount
System.
To run the Diagnostic Report, while in the Menu Mode, press 5-SETUP
from the Main Menu:
------ MAIN MENU ------
)
1-AUDIT 2-CODES 3-ACCESS
4-SCHEDULE 5-SETUP 0-END
Next, select 5-RUN DIAGNOSTICS from the Setup Menu:
------ SETUP MENU ------
)
1-STATUS REPORT 2-CLOCK
3-DEFAULTS 4-AUTOCODES
5-RUN DIAGNOSTICS
A Diagnostic Report similar to the following will print:
--DIAGNOSTICS REPORT--
OMNILOCK 300 v2.05
(C) OSI SECURITY DEVICES
LOCATION #123456 BAT:3
MON 03/01/99
DRIVE TYPE: MOTOR
DRIVE: 5810 mV
MOTOR: 1121 mV 0284 mA
SAMPLES: 12 JAMS: 00
BATTERY USAGE: 35
ELAPSED USAGE: 35
----------------------------
The Setup Menu will then reprint.
104
07:54pm