Setting The Facility Autocodes - OSI Security Devices OMNILOCK OM100 Series User Manual

Omnilock access control systems
Hide thumbs Also See for OMNILOCK OM100 Series:
Table of Contents

Advertisement

Programming in Menu Mode

Setting the Facility Autocodes

Programming Code Required:
Master Code, or
Submaster Code with menu privilege 5-SETUP
The four Facility Autocodes are used for adding User codes quickly and
reliably on one System, or multiple Systems with common Users
(Autocoding). The 6 digit Facility Autocode number acts as a 'seed' to the
code generator of the System, allowing the System to automatically generate
a different list of PIN numbers for each different Facility Autocode number.
Systems with the same Facility Autocode number will generate identical
PIN numbers.
To program the Facility Autocodes, while in Menu Mode, press 5-SETUP
from the Main Menu:
------ MAIN MENU ------
)
1-AUDIT 2-CODES 3-ACCESS
4-SCHEDULE 5-SETUP 0-END
Next, select 4-AUTOCODES from the Setup Menu:
------ SETUP MENU ------
)
1-STATUS REPORT 2-CLOCK
3-DEFAULTS 4-AUTOCODES
5-RUN DIAGNOSTICS
Then, select the number of the Facility Autocode that you wish to set from
the Facility Autocodes Menu:
)
-- FACILITY AUTOCODES --
1-123456 2-389576
3-041961 4-061061
The following prompt will print:
6 DIGIT AUTOCODE?
Enter any 6 digit number you want to use as a 'seed' to the Autocode
generator. Once you have entered the number, the Facility Autocodes Menu
will reprint with the new Facility Autocode number.