Setting the Configuration Register
To set the configuration register boot field, perform this task in privileged mode:
Task
Set the boot field in the configuration register.
This example shows how to set the boot field in the configuration register:
Console> (enable) set boot config-register boot rommon
Configuration register is 0x0
ignore-config: disabled
auto-config: non-recurring
console baud: 9600
boot: the ROM monitor
Console> (enable)
Setting the ROM-Monitor Console-Port Baud Rate
You can set the console-port baud rate used by the ROM monitor. The new baud rate is used the next
time the switch is restarted. This command affects only the configuration register bits that control the
baud rate and leaves the remaining bits unaltered.
The baud rate specified in the configuration register is used by the ROM monitor only and is different
Note
from the baud rate specified by the set system baud command.
To set the ROM-monitor console-port baud rate in the configuration register, perform this task in
privileged mode:
Task
Set the ROM-monitor console-port baud rate in
the configuration register.
This example shows how to set the ROM-monitor console-port baud rate in the configuration register to
2400:
Console> (enable) set boot config-register baud 2400
Configuration register is 0x1800
ignore-config: disabled
auto-config: non-recurring
console baud: 2400
boot: the ROM monitor
Console> (enable)
Catalyst 6000 Family Software Configuration Guide—Releases 6.3 and 6.4
23-6
Chapter 23
Modifying the Switch Boot Configuration
Command
set boot config-register boot {rommon |
bootflash | system} [mod]
Command
set boot config-register baud {1200 | 2400 | 4800
| 9600} [mod]
78-13315-02
Need help?
Do you have a question about the WS-X6066-SLB-APC - Content Switching Module and is the answer not in the manual?
Questions and answers