Chapter 22
Configuring Redundancy
Example 2: File copied, bootflash modified, standby supervisor engine not reset
The configuration for this example is as follows:
Example 3: File not copied, bootstring modified, standby supervisor engine not reset
The configuration for this example is as follows:
78-13315-02
The active supervisor engine f1 image is not copied to the standby supervisor engine.
The standby supervisor engine bootstring is not modified.
The standby supervisor engine is not reset.
The active supervisor engine configuration is as follows:
Runtime image:
bootflash:f1
Boot string:
bootflash:f1,1;
Bootflash:
f1,f2
The standby supervisor engine configuration is as follows:
Runtime image:
bootflash:f1
Boot string:
bootflash:f1,1;
Bootflash:
The time stamp for f1 on the active supervisor engine is the same as f1 on the standby supervisor
engine.
You modify the active supervisor engine bootstring to the following: f2,1;.
The expected results are as follows:
The active supervisor engine copies its f2 image to the standby supervisor engine and renames
it BTSYNC_f2.
The standby supervisor engine bootflash is modified to the following: f1, BTSYNC_f2.
The standby supervisor engine bootstring is modified to the following:
bootflash:BTSYNC_f2,1;f1,1;.
The standby supervisor engine is not reset.
The active supervisor engine configuration is as follows:
Runtime image:
bootflash:f1
Boot string:
bootflash:f1,1;
Bootflash:
f1,f2
The standby supervisor engine configuration is as follows:
Runtime image:
bootflash:f1
Boot string:
bootflash:f1,1;
Bootflash:
f1,f2
The time stamp for f1 on the active supervisor engine is the same as f1 on the standby supervisor
engine; the time stamp for f2 on the active supervisor engine is the same as f2 on the standby
supervisor engine.
The active supervisor engine bootstring is modified to the following: f2,1; f1,1;.
Catalyst 6000 Family Software Configuration Guide—Releases 6.3 and 6.4
Configuring Redundant Supervisor Engines
22-17

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WS-X6066-SLB-APC - Content Switching Module and is the answer not in the manual?

Questions and answers

Table of Contents