When Using The Inversion Output Function - Mitsubishi Electric NZ2GN2S-D41P01 User Manual

Cc-link ie tsn fpga module
Table of Contents

Advertisement

14.2

When Using the Inversion Output Function

This section describes the function to invert the digital signal input to External input signal X0 (B0), and output it from External
output signal Y0 (B0).
FPGA parameter
The setting values of the FPGA parameters to be set are shown below.
Setting item
Data sampling timing (B0)
Data update timing (B0)
Output signal selection Y0 (B0)
Input filter upper limit value X0 (B0)
User circuit part parameter
The setting values of the user circuit part parameters to be set are shown below.
Address
1000_B000H (writing data 0)
1000_B0F0H (writing data 120)
Setting method
The procedure using the FPGA Module Configuration Tool is shown below.
Operating procedure
1.
Create the project with the following settings.
Set NZ2GN2S-D41P01 as the connected main module and NZ2EX2S-D41A01 as the connection extension module.
[Project]  [New]
2.
Click the [OK] button.
3.
Enter the IP address of the FPGA module to be connected in the "Connection destination setting" window.
[Menu]  [Connection destination setting]
4.
Click the [Communication Test] button.
5.
Click the [OK] button.
6.
Click the [Apply] button.
14 SAMPLE CIRCUIT IN CC-LINK IE TSN COMMUNICATION MODE
402
14.2 When Using the Inversion Output Function
Setting item
User circuit part parameter size
Digital control part enable/disable control register (IOB0_X0 B0) (usr_wreg_000)
Digital output control digital output selection (B0) (usr_wreg_078)
Setting value
0.15s
0.1s
User circuit output
4000
Setting value
384
0003H
0000H