14.6 When Using The Pulse Output Function - Mitsubishi Electric NZ2GN2S-D41P01 User Manual

Cc-link ie tsn fpga module
Table of Contents

Advertisement

14.6
When Using the Pulse Output Function
This section describes the function to generate 100 pulses with the pulse width of 100s and output them to External output
signal Y1 (B0). Note that the digital signal is shown for 1-phase multiple of 1.
FPGA parameter
The setting values of the FPGA parameters to be set are shown below.
Setting item
Data update timing (B0)
Output signal selection Y1 (B0)
User circuit part parameter
The setting values of the user circuit part parameters to be set are shown below.
Address
1000_B0F0H (writing data 120)
1000_B220H (writing data 272)
1000_B222H (writing data 273)
1000_B224H (writing data 274)
1000_B226H (writing data 275)
1000_B260H (writing data 304)
1000_B284H (writing data 322)
14 SAMPLE CIRCUIT IN CC-LINK IE TSN COMMUNICATION MODE
414

14.6 When Using the Pulse Output Function

Setting item
User circuit part parameter size
Digital output control digital output selection (B0) (usr_wreg_078)
Pulse output part pulse width upper limit value (lower side) (B0) (usr_wreg_110)
Pulse output part pulse width upper limit value (upper side) (B0) (usr_wreg_111)
Pulse output part output pulse count upper limit value (lower side) (B0)
(usr_wreg_112)
Pulse output part output pulse count upper limit value (upper side) (B0)
(usr_wreg_113)
Pulse output part pulse output selection 0 (B0) (usr_wreg_130)
Pulse output part pulse output mask 0 (B0) (usr_wreg_142)
Setting value
0.1s
User circuit output
Setting value
384
0002H
270FH (100s)
0000H
0064H (100 pulses)
0000H
0000H
0002H