Mitsubishi Electric NZ2GN2S-D41P01 User Manual page 391

Cc-link ie tsn fpga module
Table of Contents

Advertisement

11.
Set the values of the user circuit part parameters in the "User circuit part parameter setting" window.
[Menu]  [FPGA parameter]  [User circuit part parameter setting]  <Detailed settings>
12.
Write the set parameters.
[Online]  [Parameter write (Memory + Non-volatile memory)]
13.
Click the [Yes] button.
14.
Click the [Yes] button.
Implementation method and check method
Operating procedure
1.
After writing the parameters, turn the power off and on to restart the module.
2.
Start logging.
3.
Input pulses from the encoder.
4.
After 256 records of data have been collected, FTP transfer will start.
5.
Check the file transferred over FTP.
13 SAMPLE CIRCUIT IN STANDALONE MODE
13.5 When Using the Logging Function
13
389

Advertisement

Table of Contents
loading

Table of Contents