Chapter 5 Specifications; General Specifications - Mitsubishi Electric NZ2GN2S-D41P01 User Manual

Cc-link ie tsn fpga module
Table of Contents

Advertisement

5
SPECIFICATIONS
This chapter describes the specifications of the FPGA module.
5.1

General Specifications

Item
Specifications
Operating ambient
0 to 55
temperature
Storage ambient
-25 to 75
temperature
Operating ambient
5 to 95%RH, non-condensing
humidity
Storage ambient
humidity
Vibration
Compliant with JIS
resistance
B 3502 and IEC
61131-2
Shock resistance
Compliant with JIS B 3502 and IEC 61131-2 (147m/ (15G)
Operating
No corrosive gases
atmosphere
*1
Operating altitude
0 to 2000m
Installation location
Inside a control panel
 or less
Overvoltage
*2
category
*3
Pollution degree
2 or less
Class 
Equipment class
*1 Do not use or store the FPGA module under pressure higher than the atmospheric pressure of altitude 0m.
*2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power
distribution network and the machinery within premises. Category  applies to equipment for which electrical power is supplied from
fixed facilities. The surge voltage withstand level for the equipment with up to the rated voltage of 300V is 2500V.
*3 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used.
Pollution degree 2 is when only non-conductive pollution occurs. A temporary conductivity caused by condensing must be expected
occasionally.
*4 When the acceleration is set to 9.8m/ (1G)
5 SPECIFICATIONS
32
5.1 General Specifications
Frequency
Under intermittent
5 to 8.4Hz
vibration
8.4 to 150Hz
Under continuous
5 to 8.4Hz
vibration
8.4 to 150Hz
Constant
acceleration
*4
9.8m/
4.9m/
*4
, 3 times each in X, Y, and Z directions)
Half amplitude
Number of sweeps
3.5mm
10 times each in X,
Y, and Z directions
1.75mm

Advertisement