Selection Of Waiting Time For Exit From Software Standby Mode - Hitachi H8/3032 Series Hardware Manual

Table of Contents

Advertisement

16.4.3 Selection of Waiting Time for Exit from Software Standby Mode

Bits STS2 to STS0 in SYSCR should be set as follows.
Crystal Resonator: Set STS2 to STS0 so that the waiting time (for the clock to stabilize) is at
least 8 ms. Table 16-3 indicates the waiting times that are selected by STS2 to STS0 settings at
various system clock frequencies.
External Clock: Any value may be set in the clock-halving version. Normally the minimum
value (STS2 = STS1 = STS0 = 1) is recommended. In the 1:1 clock version, any value other than
the minimum value may be set.
Table 16-3 Clock Frequency and Waiting Time for Clock to Settle
STS2 STS1 STS0 Time
0
0
0
0
1
1
Note: * This setting cannot be used in the 1:1 clock version.
Downloaded from
Elcodis.com
electronic components distributor
Waiting
16 MHZ 12 MHz 10 MHz 8 MHz 6 MHz 4 MHz 2 MHz Unit
0
0
8192
0.51
states
0
1
16384
1.0
states
1
0
32768
2.0
states
1
1
65536
4.1
states
0
131072
8.2
states
1
: Recommended setting
0.65
0.8
1.0
1.3
1.3
1.6
2.0
2.7
2.7
3.3
4.1
5.5
5.5
6.6
8.2
10.9
10.9
13.1
16.4
21.8
Illegal setting
416
2.0
4.1
ms
4.1
8.2
8.2
16.4
16.4
32.8
32.8
65.5