Bit 7—Software Standby (SSBY): Enables transition to software standby mode. When software
standby mode is exited by an external interrupt, this bit remains set to 1 after the return to normal
operation. To clear this bit, write 0.
Bit 7
SSBY
Description
0
SLEEP instruction causes transition to sleep mode
1
SLEEP instruction causes transition to software standby mode
Bits 6 to 4—Standby Timer Select (STS2 to STS0): These bits select the length of time the CPU
and on-chip supporting modules wait for the clock to settle when software standby mode is exited
by an external interrupt. If the clock is generated by a crystal resonator, set these bits according to
the clock frequency so that the waiting time will be at least 8 ms. See table 16-3. If an external
clock is used, any setting is permitted.
Bit 6
Bit 5
Bit 4
STS2
STS1
STS0
Description
0
0
0
Waiting time = 8192 states
1
Waiting time = 16384 states
1
0
Waiting time = 32768 states
1
Waiting time = 65536 states
1
0
Waiting time = 131072 states
1
Illegal setting