8.5 Interrupts

The ITU has two types of interrupts: input capture/compare match interrupts, and overflow
interrupts.

8.5.1 Setting of Status Flags

Timing of Setting of IMFA and IMFB at Compare Match: IMFA and IMFB are set to 1 by a
compare match signal generated when TCNT matches a general register (GR). The compare
match signal is generated in the last state in which the values match (when TCNT is updated from
the matching count to the next count). Therefore, when TCNT matches a general register, the
compare match signal is not generated until the next timer clock input. Figure 8-57 shows the
timing of the setting of IMFA and IMFB.
Downloaded from
Elcodis.com
electronic components distributor
ø
TCNT input
clock
N
TCNT
GR
Compare
match signal
IMF
IMI
Figure 8-57 Timing of Setting of IMFA and IMFB by Compare Match