D2: Reference Limits; D3: Jump Frequency; D4: Frequency Ref Up/Down & Hold - YASKAWA CR700 Technical Manual

Hide thumbs Also See for CR700:
Table of Contents

Advertisement

10.7 d: Reference Settings
No.
Name
(Hex.)
d1-16
Reference 16
(0291)
RUN
d1-17
Jog Reference
(0292)
RUN

d2: Reference Limits

No.
Name
(Hex.)
d2-01
Frequency Reference
Upper Limit
(0289)
d2-02
Frequency Reference
Lower Limit
(028A)
d2-03
Analog Frequency Ref
Lower Limit
(0293)

d3: Jump Frequency

No.
Name
(Hex.)
d3-01
Jump Frequency 1
(0294)
d3-02
Jump Frequency 2
(0295)
d3-03
Jump Frequency 3
(0296)
d3-04
Jump Frequency Width
(0297)
d4: Frequency Ref Up/Down & Hold
No.
Name
(Hex.)
d4-01
Freq Reference Hold
Selection
(0298)
d4-10
Up/Down Freq Lower
Limit Select
(02B6)
480
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection.
Note:
On drives with software versions PRG: 01021 and later, this function is enabled.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency Display Unit
Selection]. Set H1-xx = 6 [MFDI Function Select = Jog Reference Selection] to use the
Jog frequency reference.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets maximum limit for all frequency references. The maximum output frequency is
100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets minimum limit for all frequency references. The maximum output frequency is
100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the lower limit for the master frequency reference (the first frequency of the multi-
step speed reference) as a percentage. The maximum output frequency is 100%.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the median value of the frequency band that the drive will avoid.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the median value of the frequency band that the drive will avoid.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the median value of the frequency band that the drive will avoid.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the width of the frequency band that the drive will avoid.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to save the frequency reference when the Stop command is entered or the
drive is de-energized.
Set H1-xx [MFDI Function Select] to one of the these values to operate this parameter:
• H1-xx = A [Accel/Decel Ramp Hold]
• H1-xx = 10/11 [Up/Down Command]
The Frequency Reference Hold function depends on which function it is combined
with.
0 : Disable
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the lower frequency limit for the Up/Down function.
0 : Greater of d2-02 or Analog
1 : d2-02
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Default
Ref.
(Range)
0.00 Hz
627
(0.00 - 590.00 Hz)
6.00 Hz
628
(0.00 - 590.00 Hz)
Default
Ref.
(Range)
100.0%
628
(0.0 - 110.0%)
0.0%
628
(0.0 - 110.0%)
0.0%
628
(0.0 - 110.0%)
Default
Ref.
(Range)
0.0 Hz
629
(Determined by A1-02)
0.0 Hz
629
(Determined by A1-02)
0.0 Hz
630
(Determined by A1-02)
1.0 Hz
630
(Determined by A1-02)
Default
Ref.
(Range)
0
630
(0, 1)
0
631
(0, 1)

Advertisement

Table of Contents
loading

Table of Contents