D: Reference Settings; D1: Frequency Reference; D2: Reference Limits - YASKAWA CIPR-CR70A Series Technical Manual

Ac drive for cranes 200/400 v class: 0.4 to 110/315 kw
Table of Contents

Advertisement

d: Reference Settings

d1: Frequency Reference

No.
Name
(Hex.)
d1-01
Reference 1
(0280)
RUN
d1-02
Reference 2
(0281)
RUN
d1-03
Reference 3
(0282)
RUN
d1-04
Reference 4
(0283)
RUN
d1-05
Reference 5
(0284)
RUN
d1-06
Reference 6
(0285)
RUN
d1-07
Reference 7
(0286)
RUN
d1-08
Reference 8
(0287)
RUN
d1-17
Jog Reference
(0292)
RUN

d2: Reference Limits

No.
Name
(Hex.)
d2-01
Frequency Reference
Upper Limit
(0289)
d2-02
Frequency Reference
Lower Limit
(028A)
d2-03
Analog Frequency
Ref Lower Limit
(0293)
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency Display
Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency Display
Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency Display
Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency Display
Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency Display
Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency Display
Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency Display
Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency Display
Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Jog frequency reference in the units from o1-03 [Frequency
Display Unit Selection]. Set H1-xx = 6 [MFDI Function Select = Jog
Reference Selection] to use the Jog frequency reference.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets maximum limit for all frequency references. This value is a percentage
of E1-04 [Maximum Output Frequency].
V/f
CL-V/f
OLV
CLV
AOLV
Sets minimum limit for all frequency references. This value is a percentage
of E1-04 [Maximum Output Frequency].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the lower limit of the master frequency reference (Multi-Step Speed 1)
as a percentage of E1-04 [Maximum Output Frequency].
10 Parameter List
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
0.00 Hz
(0.00 - 590.00 Hz)
6.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
100.0%
(0.0 - 110.0%)
0.0%
(0.0 - 110.0%)
0.0%
(0.0 - 110.0%)
439