SRX1400 Services Gateway Hardware Guide
Installing a Services Processing Card in an SRX1400 Services Gateway
216
Troubleshooting Network Processing Cards on the SRX1400 Services Gateway on
page 217
You can install a SPC in the front panel of the SRX1400 Services Gateway (CFM slot 1).
Before installing your card, refer to "SRX1400 Services Gateway Front Panel" on page 14
to verify that you have selected an appropriate slot location.
NOTE: If a slot is not occupied by a card, you must install a blank panel to
shield the empty slot and to allow cooling air to circulate properly through
the device.
To install an SPC:
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
1.
ESD points on the chassis.
For more information about ESD, see "Preventing Electrostatic Discharge Damage to
the SRX1400 Services Gateway" on page 149.
Place the card on an antistatic mat or remove it from its electrostatic bag.
2.
If necessary, remove the dual-wide filler cover from the slot by loosening its screws
3.
and sliding it out of the slot.
Insert the double wide tray holder and insert it straight into the slot until you hear a
4.
click, indicating the latch has closed as shown in Figure 69 on page 216.
Figure 69: Installing Double Wide Tray Holder on SRX1400 Services
Gateway
Orient the SPC so that the faceplate faces you. Slide the SPC all the way into the card
5.
cage until you feel resistance. See Figure 70 on page 217.
Copyright © 2011, Juniper Networks, Inc.