Replacing AC Power Supply Cables on the SRX1400 Services Gateway

134
NOTE: You must have a SYSIOC and a Routing Engine installed in the
services gateway for the power supply to turn on automatically.
NOTE: If you are moving this power supply from one slot to another, wait
at least 60 seconds before inserting it into the new slot.
NOTE: To maintain proper cooling and prevent thermal shutdown of the
operating power supply unit, each power supply slot must contain either a
power supply or a blank panel. If you remove a power supply, you must install
a replacement power supply or a blank panel shortly after the removal.
WARNING: Before working on an AC-powered device or near power supplies,
unplug the power cord.
To replace an AC power supply cord:
Unplug the power cord from the power source receptacle.
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
2.
ESD points on the chassis. For more information about ESD, see "Preventing
Electrostatic Discharge Damage to the SRX1400 Services Gateway" on page 149.
Unplug the power cord from the appliance inlet on the power supply.
3.
Locate a replacement C13 power cord with the type of plug appropriate for your
4.
geographical location.
Insert the power cord plug into an external AC power source receptacle.
5.
Connect the power cord to the power supply. See Figure 48 on page 134.
6.
Figure 48: Connecting AC Power Supply Cables on the SRX1400 Services
Gateway
Copyright © 2011, Juniper Networks, Inc.