SRX1400 Services Gateway Hardware Guide

Installing a Network Processing Card in an SRX1400 Services Gateway

214
Installing a Services Processing Card in an SRX1400 Services Gateway on page 216
Troubleshooting Services Processing Cards on the SRX1400 Services Gateway on
page 218
Replacing a Services Processing Card on the SRX1400 Services Gateway on page 220
Locating the Services Processing Card Serial Number Label on page 223
You can install an NPC in the front panel of the SRX1400 Services Gateway (CFM slot
3).
Before installing your card, see "SRX1400 Services Gateway Front Panel" on page 14 to
verify that you have selected an appropriate slot location.
NOTE: If a slot is not occupied by a card, you must install a blank panel to
shield the empty slot and to allow cooling air to circulate properly through
the device.
NOTE: To install the NPC and SPC on the SRX1400 Services Gateway, you
must order the double wide tray holder (SRX1K3K-2CFM-TRAY) to hold two
single-wide CFMs (NPC and SPC) separately. Contact your Juniper Networks
customer service representative for more information.
To install an NPC:
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
1.
ESD points on the chassis. For more information about ESD, see "Preventing
Electrostatic Discharge Damage to the SRX1400 Services Gateway" on page 149.
Place the card on an antistatic mat or remove it from its electrostatic bag.
2.
If necessary, remove the filler cover from the slot by loosening its screws and sliding
3.
it out of the slot.
Insert the double wide tray holder and insert it straight into the slot until you hear a
4.
click, indicating the latch has closed as shown in Figure 67 on page 215.