CHAPTER 13
Replacing Hardware Components on the
SRX1400 Services Gateway

Field-Replaceable Units on the SRX1400 Services Gateway

Copyright © 2011, Juniper Networks, Inc.
This chapter includes the following topics:
Field-Replaceable Units on the SRX1400 Services Gateway on page 113
Required Tools and Parts for Replacing Hardware Components on the SRX1400
Services Gateway on page 114
Replacing Cooling System Components on the SRX1400 Services Gateway on page 115
Replacing Host Subsystem Components on the SRX1400 Services Gateway on page 120
Replacing Power System Components on the SRX1400 Services Gateway on page 132
Field-replaceable units (FRUs) are services gateway components that can be replaced
at the customer site. The device uses the following types of FRUs:
Hot-removable and hot-insertable-FRUs —You can remove and replace these
components without powering off the device or disrupting the routing functions.
Cold-Swap-Only FRUs —You must power off the device in order to remove, replace,
or add these components.
Table 35 on page 113 lists the FRUs for the services gateway.
Table 35: Field-Replaceable Units
Hot-Removable and Hot-Insertable FRUs
Air filters (cooling system)
Air filters (power supply) (if redundant)
Fan trays
AC and DC power supplies (if redundant)
Small form-factor pluggable (SFP) and
SFP+
Cold-Swap-Only FRUs
Routing Engine
System I/O card (SYSIOC)*
I/O card (IOC)
Network and Services Processing Card
(NSPC)*
113