Replacing Sfp And Xfp Transceivers On I/O Cards On The Srx1400 Services Gateway - Juniper SRX1400 Hardware Manual

Services gateway
Hide thumbs Also See for SRX1400:
Table of Contents

Advertisement

SRX1400 Services Gateway Hardware Guide

Replacing SFP and XFP Transceivers on I/O Cards on the SRX1400 Services Gateway

128
Figure 44: Installing the SYSIOC from the SRX1400 Services Gateway
Tighten the captive screws on the left and right of the SYSIOC faceplate.
12.
Insert the appropriate cables into the cable connector ports on each SYSIOC.
13.
Power on the services gateway, as described in "Powering On the SRX1400 Services
14.
Gateway" on page 82.
The
SYSIO
LED on the SYSIOC faceplate should blink green, then light steadily.
NOTE: If the
SYSIO
LED remains red, the SYSIOC is not functioning properly. Contact
your customer support representative.
Check the status of the SYSIOC by using the
15.
WARNING: Never lift the services gateway using the handles on the front
panels of the IOCs or other CFM cards. The handles might come off, causing
the chassis to drop and inflicting possible grave injury.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not
allow fastened loops of cable to dangle, which stresses the cable at the
fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius.
An arc smaller than a few inches in diameter can damage the cable and cause
problems that are difficult to diagnose.
The small form-factor pluggable transceivers (SFPs) and XFPs are optical transceivers
that are installed in IOC. SFPs and XFPs are hot-insertable and hot-removable. Removing
LED is red, remove and reinstall the SYSIOC. If the
SYSIO
show chassis environment fpc 0
command.
Copyright © 2011, Juniper Networks, Inc.