Juniper SRX1400 Hardware Manual page 84

Services gateway
Hide thumbs Also See for SRX1400:
Table of Contents

Advertisement

SRX1400 Services Gateway Hardware Guide
64
NOTE: If an NSPC is not present, you must install a filler cover to shield the
empty slots 1 and 3 and to (shown in Figure 24 on page 64) to shield the empty
slot and to allow cooling air to circulate properly through the device.
Figure 24: SRX1400 Services Gateway with NSPC Slot Covered by
Dual-Wide Filler Cover
To install an NSPC:
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
1.
ESD points on the chassis.
For more information about ESD, see "Preventing Electrostatic Discharge Damage to
the SRX1400 Services Gateway" on page 149.
Place the card on an antistatic mat or remove it from its electrostatic bag.
2.
Identify the slot on the services gateway where you will install the NSPC.
3.
See "SRX1400 Services Gateway Front Panel" on page 14 for details about where the
individual modules can be installed.
Remove the dual-wide filler cover from the slot by loosening its screws and sliding it
4.
out of the slot. Save the filler cover after removing it from the slot, in case you need
it when you pack or move the chassis at a later time.
Orient the NSPC so that the faceplate faces you. Slide the NSPC all the way into the
5.
card cage until you feel resistance. See Figure 25 on page 64.
Figure 25: Installing a Network and Services Processing Card in an
SRX1400 Services Gateway