Replacing Power System Components on the SRX1400 Services Gateway

Replacing an AC Power Supply on the SRX1400 Services Gateway

132
Slide the transceiver until the connector is seated in the SYSIOC slot. If you are unable
15.
to fully insert the transceiver, make sure the connector is facing the right way.
Close the ejector handle of the transceiver.
16.
Remove the rubber safety cap from the transceiver and the end of the cable. Reconnect
17.
the cables into the transceivers.
Verify that the status LEDs on the SYSIOC faceplate indicate that the SFP or SFP+ is
18.
functioning correctly. You can also verify that the SYSIOC is functioning by issuing the
show chassis fpc pic-status
This topic includes the following sections:
Replacing an AC Power Supply on the SRX1400 Services Gateway on page 132
Replacing AC Power Supply Cables on the SRX1400 Services Gateway on page 134
Replacing a DC Power Supply on the SRX1400 Services Gateway on page 135
Replacing DC Power Supply Cables on the SRX1400 Services Gateway on page 138
Replacing the Power Supply Air Filter on the SRX1400 Services Gateway on page 138
To replace an AC power supply:
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
1.
ESD points on the chassis. For more information about ESD, see "Preventing
Electrostatic Discharge Damage to the SRX1400 Services Gateway" on page 149.
Remove the power cord from the power supply.
2.
Push the tab on the left edge of the power supply to the right.
3.
Pull the power supply straight out of the chassis using the provided handle. Use one
4.
hand to support underneath the supply as you remove it. See Figure 46 on page 132.
Figure 46: Removing an AC Power Supply from the SRX1400 Services
Gateway
Orient the replacement power supply so that the tab is on the left side.
5.
command.