Installing The Srx1400 Services Gateway In A Rack Or Cabinet Manually (Without A Mechanical Lift); Installing The Srx1400 Services Gateway In A Rack Or Cabinet Manually - Juniper SRX1400 Hardware Manual

Services gateway
Hide thumbs Also See for SRX1400:
Table of Contents

Advertisement

SRX1400 Services Gateway Hardware Guide
Installing the SRX1400 Services Gateway in a Rack or Cabinet Manually (Without a
Mechanical Lift)

Installing the SRX1400 Services Gateway in a Rack or Cabinet Manually

58
This topic includes the following sections:
Installing the SRX1400 Services Gateway in a Rack or Cabinet Manually on page 58
Required Tools for Installing the SRX1400 Services Gateway Manually on page 59
Removing Components from the Chassis for Manual Lifting of the SRX1400 Services
Gateway on page 59
Lifting the SRX1400 Services Gateway Chassis into a Rack on page 60
Reinstalling Components into the SRX1400 Services Gateway Chassis on page 62
If you cannot use a mechanical lift to install the SRX1400 Services Gateway (the preferred
method), you can install it manually. Before installing the services gateway manually,
you must first remove components from the chassis, and you must reinstall the
components once the services gateway is installed in the rack.
NOTE: We recommend removing the components from the chassis before
installing to prevent damage to the components.
At least two people are needed to safely lift the chassis into the rack or cabinet. With
components removed, the chassis weighs approximately 23.30 lb (10.57 kg).
CAUTION: If a slot is not occupied by a card, you must install a blank panel
to shield the empty slot to prevent foreign objects from damaging the exposed
electronics.
Before installing the services gateway in the rack:
Read the safety information in "Chassis Lifting Guidelines" on page 151.
Remove the services gateway from the shipping container as described in "Unpacking
the SRX1400 Services Gateway" on page 47.
Install the mounting hardware as described in "Installing the Mounting Hardware for
the SRX1400 Services Gateway" on page 54.
Installing the SRX1400 Services Gateway in a rack or cabinet Manually involves the
following steps:
Remove the components from chassis to reduce the weight. For more information,
1.
see "Removing Components from the Chassis for Manual Lifting of the SRX1400
Services Gateway" on page 59.
Copyright © 2011, Juniper Networks, Inc.