Chapter 13: Replacing Hardware Components on the SRX1400 Services Gateway
CAUTION: Do not run the services gateway for more than a few minutes
without the air filter in place.
NOTE: You can order an air filter kit separately. Contact your Juniper Networks
customer service representative for more information. The air filter kit includes
a cooling system air filter and a power supply air filter.
To replace the air filter:
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
1.
ESD points on the SRX1400 chassis. For more information about ESD, see "Preventing
Electrostatic Discharge Damage to the SRX1400 Services Gateway" on page 149.
Figure 52 on page 139 shows the SRX1400 Services Gateway power supply air filter.
Figure 52: SRX1400 Power Supply Air Filter
2
3
1
Table 38 on page 139 lists the SRX1400 services gateway power supply air filter
components.
Table 38: Power Supply Air Filter Components
Number
1
2
3
The numbers in Figure 52 on page 139 on page 10 correspond to the numbers in Table
38 on page 139.
Using a number-2 Phillips screwdriver, loosen the screws (removable self-tap screws,
2.
no. 3) on the power supply air filter plastic holder.
Remove the plastic holder of the power supply air filter.
3.
Slide the air filter out of the plastic holder and dispose the air filter.
4.
Power Supply Air Filter Components
Removable self-tap screws
Plastic holder
Air Filter
139