Chapter 13: Replacing Hardware Components on the SRX1400 Services Gateway
WARNING: To avoid injury, do not proceed until the fans have stopped
spinning.
WARNING: The fan tray LED provides additional safety measures. Even
though you can remove the fan tray while fans are still running, we that
you wait until the fan tray LED lights steadily amber (indicating that the
fans are not running) before you remove the fan tray.
After the fans have stopped spinning and the fan tray LED lights steadily, lift upward
5.
on the latch at the bottom of the fan tray to release it as shown in Figure 33 on page 117.
Figure 33: Removing the Fan Tray from the SRX1400 Services Gateway
Grasp the fan tray and pull it out approximately 6 in. (15 cm).
6.
Place one hand under the fan tray to support it and pull the fan tray completely out
7.
of the chassis. Set it aside.
Grasp the replacement fan tray and insert it straight into the chassis until you hear a
8.
click, indicating the latch has closed. See Figure 34 on page 118.
117