Installing the SRX1400 Services Gateway in a Rack or Cabinet Using a Mechanical Lift

Copyright © 2011, Juniper Networks, Inc.
CAUTION: If a slot is not occupied by a card, you must install a blank panel
to shield the empty slot to prevent foreign objects from damaging the exposed
electronics.
You can front-mount or rear-mount the services gateway in a two-post rack, a four-post
rack, or a cabinet. This topic provides the installation instructions on front-mounting of
the device in a two-post rack.
To install an SRX1400 Services Gateway in a rack or cabinet:
Ensure the rack is in its permanent location and is secured to the building.
1.
Ensure that the installation site allows adequate clearance for both airflow and
2.
maintenance. For details, see "Site Preparation Checklist for the SRX1400 Services
Gateway" on page 41.
Load the device onto the lift, making sure it rests securely on the lift platform (see
3.
Figure 20 on page 56).
Chapter 5: Installing the SRX1400 Services Gateway
55