Installing A System I/O Card Into The Srx1400 Services Gateway - Juniper SRX1400 Hardware Manual

Services gateway
Hide thumbs Also See for SRX1400:
Table of Contents

Advertisement

Related
Documentation

Installing a System I/O Card into the SRX1400 Services Gateway

Related
Documentation
Copyright © 2011, Juniper Networks, Inc.
Chapter 6: Installing Additional Components into the SRX1400 Services Gateway
Press both of the ejector handles inward to seat the NSPC.
6.
Tighten the screws on either side of the card.
7.
You can proceed with installing other hardware components, or power supplies, or
connecting to a management device. See "Powering On the SRX1400 Services
Gateway" on page 82 to power on the SRX1400 Services Gateway.
Installing a Network Processing Card in an SRX1400 Services Gateway on page 214
Installing a Services Processing Card in an SRX1400 Services Gateway on page 216
SRX1400 Services Gateway Hardware Components on page 13
Before installing your card, see "SRX1400 Services Gateway Front Panel" on page 14 to
verify that you have selected an appropriate slot location.
To install a SYSIOC on an SRX1400 Services Gateway:
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
1.
ESD points on the chassis.
For more information about ESD, see "Preventing Electrostatic Discharge Damage to
the SRX1400 Services Gateway" on page 149.
Place the SYSIOC on an antistatic mat or remove it from its electrostatic bag.
2.
Identify the slot on the services gateway where you will install the SYSIOC.
3.
See "SRX1400 Services Gateway Front Panel" on page 14 for details about where the
individual modules can be installed.
Orient the SYSIOC so that the faceplate faces you. Slide the SYSIOC all the way into
4.
the card cage until you feel resistance.
Press both of the ejector handles inward to seat the SYSIOC.
5.
Tighten the screws on either side of the card.
6.
Insert the appropriate cables into the cable connector ports (ports 0-5) and small
7.
form-factor pluggable (SFP) transceivers (ports 6-11) on SYSIOC as required. Secure
the cables so that they are not supporting their own weight. Place excess cable out
of the way in a neatly coiled loop. Placing fasteners on a loop helps to maintain its
shape.
You can proceed with installing other hardware components, or power supplies, or
connecting to a management device. See "Powering On the SRX1400 Services Gateway"
on page 82 to power on the SRX1400 Services Gateway.