Performing System Diagnostics
2
From the NAND EEPROM/DOSFS Menu you can do the following:
•
Test the read/write functionality of the NAND EEPROM by typing t then pressing
ENTER
. The system runs a test and reports the results on the screen.
•
View a directory of the files contained in the management card NVRAM by type d
then pressing
successfully downloaded from the boot server.
•
Specify a file to boot from the management card by typing l <filename> then
pressing
file you want to load. You may want to do this to load a different image file than the
file that is set as the default boot file.
•
View the content of any text file by typing r <filename> then pressing
where <filename> is the complete filename and extension of the file you want to
view.
•
To make the amcprof.txt file on the management card read-only, type n. The
amcprof.txt file contains the management card hardware and software serial and
revision numbers.
•
To view binary image file information, such as the version number, processor name
and revision number, type v <filename> where <filename> is the complete
file name and extension of the binary file for which you want to view information.
•
If the EEPROM Test (option t) fails, which indicates that the EEPROM has been
corrupted, type u then press
reformatted (restored to its original factory condition).
•
Type x then press
Testing the TRAM CUBIT
From the DMU Test Main Menu, type 3 then press
reports the results on the screen, and displays the DMU Test Main Menu.
600
ENTER
. You may want to do this to verify that the image file was
ENTER
, where <filename> is the complete filename and extension of the
ENTER
ENTER
to return to the DMU Test Main Menu.
to reformat the EEPROM. The EEPROM is
ENTER
. The system tests the CUBIT,
Avidia System Configuration and Management User Manual
ENTER
,