Monitoring SDSL Frame Alarm History

You view the SDSL frame alarm history from the ::alarm=> prompt. From the ::root=>
prompt, type the following command then press
display alarm
To display SDSL frame alarm history, type the sdsl command as follows then press
sdsl [<port>]
Parameter
[<port>]
The number of the SDSL port for which you want to display alarm history. Omitting this
parameter displays alarm history for all SDSL ports.
Examples
::alarm=> sdsl 3.1
::alarm=> sdsl
A screen similar to the following displays.
::alarm=>sdsl 3.1
Margin Alarm:
Errored Seconds Alarm:
Unavailable Seconds Alarm:
Loss of Sync Word Alarm:
Avidia System Configuration and Management User Manual
SDSL ALARM HISTORY OF PORT 3.1
First Occurred
0:00:31 01/01/1999
n/a
n/a
n/a
Chapter 16: Monitoring System Alarms and Status
ENTER
to display the ::alarm=> prompt.
Last Occurred
0:00:31 01/01/1999
n/a
n/a
n/a
ENTER
.
Count
1
0
0
0
333