Configuring IDSL Alarm Profiles
Examples
::alarm=> show 1
::alarm=> show
The following screen shows an example of both show alarm commands.
::alarm=> show 1
Hourly
Index
ES
1
40
::alarm=> show
Hourly
Index
ES
1
40
2
40
3
50
Information
Index
Hourly ES
Hourly SES
Daily ES
Daily SES
132
Hourly
Daily
SES
ES
10
100
Hourly
Daily
SES
ES
10
100
15
100
10
125
Description
The index number of the alarm profile
The number of errored seconds that must be met or
exceeded on the IDSL line within an hour for a trap to
occur. The range is 0 (disable) to 255.
The number of severely errored seconds that must be
met or exceeded on the IDSL line within an hour for a
trap to occur. The range is 0 (disable) to 127.
The daily ES threshold is the number of errored
seconds that must be met or exceeded on the IDSL
line within a day for a trap to occur. The range is 0
(disable) to 4095.
The number of severely errored seconds that must be
met or exceeded on the IDSL line within a day for a trap
to occur. The range is 0 (disable) to 2047.
Avidia System Configuration and Management User Manual
Daily
SES
25
Daily
SES
25
30
25
.