Monitoring System Alarms and Events

M
ONITORING
You monitor system alarms and events from the ::admin=> prompt. From the ::root=>
prompt, type admin then press
To display information about alarms and events that have occurred since the system was
powered up, including internal alarms such as memory and system fans, from the ::admin=>
prompt type the log command in the following format then press
log (alarm|all|debug|error|info|trace)
Parameter
(alarm|all|debug|error|info|trace)
alarm displays the alarms that have occurred since the system was powered up
all displays all system events, including alarms, traps, changes in slot status and
diagnostic traces
debug is for technician use only
error is for technician use only
info is for technician use only
trace is for technician use only
Examples
::admin=>log alarm
::admin=>log all
When you type log alarm, a screen similar to the following displays.
::admin=>log alarm
Timestamp
THU DEC 23 06:50:40 1999
THU DEC 23 06:50:40 1999
328
S
A
YSTEM
LARMS AND
ENTER
to display the ::admin=> prompt.
Type
Slot
Description
alarm
Critical, Alarm#100:chassis power alarm
alarm
4
No Alarm, Alarm #104:chassis line card
down
E
VENTS
ENTER
Avidia System Configuration and Management User Manual
.