Configuring Frame Relay Frf.8 Circuits - ADC AVIDIA SWD4573I1 User Manual

System configuration and management
Table of Contents

Advertisement

Status Box
Link
State
PollInt
FullEnqInt
ErrThreshold
MonEvents
C
ONFIGURING
FRF.8 defines how frames are translated between ATM and frame devices.
You configure frame relay FRF.8 circuit parameters from the ::frf8=> prompt. From the
::root=> prompt, type the following command then press
prompt.
configuration frame-relay frf8
Avidia System Configuration and Management User Manual
Description
The channel card slot and port (format slot.port).
The LMI (Local Management Interface) type, which
defines a method of exchanging status information
between the customer device and the network. The
options are:
LMI—LMI Rev-1
ANNEXA—ITU 0.933 Annex-A
ANNEXD—ANSI T1 617 Annex-D
NONE—no LMI support
If the LMI type is set to NONE, the poll interval, inquiry
interval, error threshold, and monitor events
parameters are not used.
The poll interval value, which is the number of seconds
between LMI status inquiry messages (range: 5-30).
The enquiry interval value, which is the number of poll
intervals before a full status inquiry message is sent
(range: 1-255).
The error threshold value, which is the number of
consecutive poll intervals in which the LMI status
inquiry messages are not received that are required for
the link to be declared down (range: 1-10).
The monitor events value, which is the number of poll
intervals in which the LMI status inquiry messages are
not received that are required for the link to be
declared down (range: 1-10).
F
R
RAME
ELAY
Chapter 9: Configuring Frame Relay Interworking
FRF.8 C
IRCUITS
ENTER
to display the ::frf8=>
211