Configuring Frame Relay Links; Adding A Frame Relay Link - ADC AVIDIA SWD4573I1 User Manual

System configuration and management
Table of Contents

Advertisement

Configuring Frame Relay Links

C
ONFIGURING
You configure frame relay link parameters from the ::link=> prompt. From the ::root=>
prompt, type the following command then press
configuration frame-relay link

Adding a Frame Relay Link

From the ::link=> prompt, type the new command in the following format then press
ENTER
.
new <slot.port> [-lmitype (LMI|ANNEXA|ANNEXD|NONE)]
[-pollinterval <int>] [-enqinterval <int>] [-errthreshold <val>]
[-monevents <val>]
Parameters
<slot.port>
The channel card slot and port (format slot.port).
[-lmitype (LMI|ANNEXA|ANNEXD|NONE)]
The LMI (Local Management Interface) type defines a method of exchanging status
information between the customer device and the network. The options are:
LMI—LMI Rev-1
ANNEXA—ITU 0.933 Annex-A
ANNEXD—ANSI T1 617 Annex-D
NONE—no LMI support
If the LMI type is set to NONE, the poll interval, inquiry interval, error threshold,
and monitor events parameters are not used.
[-pollinterval <int>]
The poll interval value in seconds. Poll Interval is the number of seconds between LMI
status inquiry messages. The valid range is 5 to 30, with 15 as the default.
206
F
R
RAME
ELAY
L
INKS
ENTER
to display the ::link=> prompt.
Avidia System Configuration and Management User Manual