Monitoring SONET Performance
Monitoring SONET Section Statistics
From the ::sonet=> prompt, type the section command in the following format then press
ENTER
.
section [<port>] [-interval (<number>|all)]
Parameter
[<port>]
Specifies a particular port for which to display statistics (format slot.port). Each OC3 line
card has two SONET fiber ports, which are identified by 1a and 1b. Omitting this parameter
displays statistics for all SONET ports.
[-interval (<number>|all)
Specifies the 15-minute reporting interval for which the statistics are displayed. Typing
-interval all displays the entire 24-hour history. Omitting this parameter displays
the current status.
<number>
Type a number from 1 to 96, where 1 represents the most recent 15-minute reporting
interval and 5 represents the fifth most recent 15-minute reporting interval.
Examples
::sonet=> section 12.1a -interval 5
::sonet=> section
The following screen illustrates both section commands.
::sonet=> section 12.1a -interval 5
Port
ESs
12.1a
0
::sonet=> section
Port
Status
12.1a
LOF
12.1b
LOF
280
SESs
SEFSs
CVs
0
0
0
ESs
SESs
SEFSs
0
0
0
0
0
0
Interval
5
CVs
0
0
Avidia System Configuration and Management User Manual