Configuring Traffic
Parameters
Commands
®
1-Port Channelized STS-1e, T1 Format Module User Guide, Issue 1
PacketStar
255-700-184
Chapter 7 Provisioning Connections Using the Console Interface
Adding a Circuit Emulation-to-Circuit Emulation PVC Connection
End
To configure the traffic parameters for this connection, perform the steps in
the following procedure.
Steps to Configure Traffic Parameters
Begin
1 On the Frame Relay-to-Frame Relay PVC Connection window (see
Figure 7-23), select Configure Traffic Parameters and press Enter.
The Frame Relay-to-Frame Relay PVC Traffic Parameters window is
displayed (see Figure 7-24).
Figure 7-24. Frame Relay-to-Frame Relay PVC Traffic Parameters Window
The commands on this window have the following functions:
Command
• Add This Connection
Function
Adds a connection having the values cur-
rently displayed on the window.