Verifying the Initial Startup
Configuring the Module
Troubleshooting the Installation
Removing the Module
Page 4 of 6
3 Hand tighten the two captive screws on the module, then tighen with a flat-
head screwdriver.
4 Connect the appropriate cables to the module.
End
Verify that the status indicators (
normal traffic flow. If they are illuminated, the received input signal is not
detected. The same status indicators also appear on the PSAX protection mod-
ules.
The LIM3–1 module does not have any configurable components. However, the
installed PSAX protection modules are configurable, see the appropriate PSAX
module user guide for details.
If you experience a problem with the LIM3–1 module, refer to the Lucent Technol-
ogies Product Warranty Registration Information, which accompanied your shipment,
for instructions on obtaining support in your area.
Perform the following procedure to remove the LIM3–1 module from the
PSAX 1000 chassis.
Removing the LIM3-1
Begin
1 Verify that the network connections are not passing traffic and disconnect
the cables from the module ports.
2 Loosen the two captive screws holding the module in place with a flathead
screwdriver.
3 Pull the module out of the slot.
4 Put the module in its ESD packaging, and place the module in its original
shipping box.
5 If another module is not being immediately inserted into the empty slot,
insert a LIM blank faceplate into the slot to prevent EMI and maintain proper
air flow inside the chassis.
!
CAUTION:
Ultimate disposal of this product should be handled according to all laws
and regulations in your specific geographic region.
End
LOS
) on the module are not illuminated during
PacketStar
PSAX 1000 3-Port Line Interface Module Description and Specifications
®