Virtual Port Configuration - Lucent Technologies PacketStar PSAX Series User Manual

1-port channelized sts-1e, t1 format module
Hide thumbs Also See for PacketStar PSAX Series:
Table of Contents

Advertisement

Virtual Port
Configuration
®
1-Port Channelized STS-1e, T1 Format Module User Guide, Issue 1
PacketStar
255-700-184
Chapter 4 Configuring Ports and Channels Using the AQueView
Table 4-2. Field Descriptions for the Channelized STS1-e Port Configuration Page
(Physical DS3 Port)
Field Names
Line Status
NoAlarm
(display only)
RcvRAIFailure
Note: See the
bit map tables
XmitRAIAlarm
for the 1-Port
Channelized
RcvAIS
STS-1e,
XmitAIS
T1 Format
module under
LOF
the MIB object
LOS
lineStatus in the
LoopbackState
"SNMP Trap
Messages"
RcvTestCode
appendix in any
OtherFailure
®
PacketStar
RcvRmtAIS
PSAX
Multiservice
Media Gateway
RcvRmtOOF
user guide
RcvRmtLOS
RcvRmtIdle
RmtLoopback
3 Click Apply.
End
Perform the steps in the following procedure to configure virtual ports on the
1-Port Channelized STS-1e, T1 Format module.
Configuring the Virtual STS1 Ports
Begin
1 Click the Virtual Port Configuration tab.
The Virtual Port Configuration page is displayed (see Figure 4-9).
Values
No alarm present.
Receiving Yellow/Remote Alarm Indica-
tion.
Transmitting Yellow/Remote Alarm
Indication.
Receiving AIS failure state.
Transmitting AIS failure state.
Receiving LOF failure state.
Receiving LOS failure state.
Looping the received signal.
Receiving a Test Pattern.
Any line status that is undefined.
Receiving Remote Alarm Indicator Sig-
nal
Receiving Remote Alarm Out of Frame
Signal
Receiving Remote LOS
Receiving Remote Idle
Far end remote loopback.
®
System
Using the Right-Click Menu
Description
Release 7.0
4-9

Advertisement

Table of Contents
loading