Primary Page - Lucent Technologies PacketStar PSAX Series User Manual

1-port channelized sts-1e, t1 format module
Hide thumbs Also See for PacketStar PSAX Series:
Table of Contents

Advertisement

Chapter 8 Provisioning Connections Using the AQueView
Creating ATM-to-ATM VPC PVC Connections
Table 8-19. Field Descriptions for the In-Band ATM PVC Connection Configuration Window
Field Name
Sustained Cell
Default: 1
Rate (cps)
Max Burst Size
Default: 1
(cells)
Connection
Inactive
Status
(default)
(display only)
Active
Connection
None (default)
Failure Cause A
Physical
(display only)
Connection
None (default)
Failure Cause B
Physical
(display only)

Primary Page

®
1-Port Channelized STS-1e, T1 Format Module User Guide, Issue 1
PacketStar
8-112
Values
Sustainable cell rate (SCR) with CLP=0 (high priority) cells
or the peak cell rate with CLP=0 cells.
When setting this value, take into account the line rate for
the module and the amount of bandwidth you are setting
up for each interface for the module. Refer to the ATM UNI
3.1 specifications for more information.
If you select the value SimplexA2B in the Traffic Flow
field, set the value of this field to 0. The value in this field
should be less than the Peak Cell Rate field.
Refer to the ATM UNI 3.1 specifications for more informa-
tion. When setting this value, take into account the line
rate for the module and amount of bandwith you are set-
ting up for each interface on the module.
This field displays the current status of the connection. The
value indicates whether the connection is passing traffic.
General connection failure cause.
General connection failure cause.
If the parameters are valid, the Connections window appears with the
new connection in the Listing page, and the Display Connection
window appears with tabs that contain details about the connection (see
Figure 8-60): Primary and Backup (if a backup connection was
established).
If a parameter is invalid, a Connection Creation Failed message appears,
stating the reason for the failure.
The Primary page displays the information used to create the connection.
See Table 8-19 for field descriptions.
®
System
Description
Release 7.0
255-700-184

Advertisement

Table of Contents
loading