Advertisement

Chapter 7 Provisioning Connections Using the Console Interface
Adding a Circuit Emulation-to-Circuit Emulation PVC Connection
Table 7-13. Field Descriptions for the Frame Relay-to-ATM VCC PVC Traffic Parameters Window
Field Name
Committed Info
Default: 0
Rate
Interworking
Default:
Function
Frf8-Transl,
Frf8-Pass,
Frf5
[Time Interval]
Default: 1000
(display only)
[Peak Cell Rate]
Default: 1
(display only)
[Sustained Cell
Default: 1
Rate]
(display only)
[Max Burst
Default: 1
Size]
(display only)
Viewing the Statistics
Window
®
1-Port Channelized STS-1e, T1 Format Module User Guide, Issue 1
PacketStar
7-54
Values
Committed information rate is the rate of traffic
(measured in bits per second) for a given connection that
the system will attempt to provide guaranteed delivery.
FRF.8 (Frame Relay Forum Implementation Agree-
ment)—frame relay to ATM PVC service interworking.
FRF.5 (Frame Relay Forum Implementation Agree-
ment)—frame relay to ATM PVC service interworking.
Time, in seconds, since the last reset.
Refer to the ATM UNI 3.0 specifications for more informa-
tion. When setting this value, take into account the line
rate for the module and the amount of bandwidth you are
setting up for each interface for the module.
Sustained cell rate. Refer to the ATM UNI 3.0 specifica-
tions for more information. When setting this value, take
into account the line rate for the module and the amount
of bandwidth you are setting up for each interface for the
module.
Maximum burst size. Refer to the ATM UNI 3.0 specifica-
tions for more information. When setting this value, take
into account the line rate for the module and the amount
of bandwidth you are setting up for each interface for the
module.
3 To add (apply) the connection configuration, select the Add This
Connection command and press Enter.
4 To review this connection, select the Go Back to Connection Table
command and press Enter (or press Ctrl+B).
The Frame Relay-to-ATM VCC PVC Table window returns, displaying
the values you just applied.
5 To add more connections of this type, repeat steps 2 through 5 for more
connections as needed.
End
From the Frame Relay-to-ATM PVC window, select the View Statistics
command.
The Frame Relay-to-ATM PVC Statistics window is displayed (see
Figure 7-21).
Description
Release 7.0
255-700-184