Chapter 5 Configuring the Interfaces Using the Console Interface

Configuring the Circuit Emulation Interface

Table 5-9. Field Descriptions for the ILMI Statistics Window
Field Name
[AttachPt Verified]
(display only)
[Secure Link Proc Initiated]
(display only)
[ILMI Timeouts]
(display only)
[Packet Discarded]
(display only)
[Coldstart Tx]
(display only)
[Coldstart Rx]
(display only)
[Pdu Rcvd]
(display only)
[Pdu Txed]
(display only)
[Time Elapsed]
(display only)
Configuring the Circuit Emulation Interface
®
1-Port Channelized STS-1e, T1 Format Module User Guide, Issue 1
PacketStar
5-34
Number of times attachment point was verified successfully.
Number of times the secure link procedure was initiated.
Number of times the Get Request of any type was timed out.
Number of times a packet (pdu) was discarded due to format
error.
Number of times a Cold Start trap message was transmitted.
Number of times a Cold Start trap message was received.
Total number of packets received.
Total number of packets transmitted.
Time, in seconds, since last reset.
End
This section provides instructions for configuring an I/O module for the
Circuit Emulation interface.
Configuring the Circuit Emulation Interface
Begin
1 When you select the value CircuitEmulation as the interface type on the
Port and Channel configuration window, the Circuit Emulation
Interface Configuration window (see Figure 5-11) is displayed.