Chapter 3 Configuring Ports and Channels Using the Console Interface

Saving the Equipment Configuration and Logging Off

Saving the Equipment Configuration and Logging Off
®
1-Port Channelized STS-1e, T1 Format Module User Guide, Issue 1
PacketStar
3-24
Table 3-5. Field Descriptions for the Channelized STS1 Virtual Port DS1 Statistics
Window
Field Name
Path Coding
A frame synchronization bit error in the D4 and E1-
Violations
noCRC formats, or a CRC error in the ESF (Extended
(display only
Super Frame) and E1-CRC formats.
The number of Path Coding Violations encountered by
DS1 in the previous 24-hour period.
Line Errored Sec-
A second in which one or more Line Code Violation
onds
error events were detected.
(display only)
The number of Line Errored Seconds encountered by
DS1 in the previous 24-hour period.
Bursty Errored
A second with fewer than 320 and more than 1 Path
Seconds
Coding Violation error events, no Severely Errored
(display only)
Frame defects, and no detected incoming AIS defects.
The number of bursty errored seconds encountered by
DS1 in the previous 24-hour period.
Line Coding Vio-
A bipolar violation or excessive zeroes error event has
lations
occurred.
(display only)
After configuring the module ports and channels, the interface types for each
port and channel, and the connections, you must save the configuration
permanently, before you exit the current session for the PSAX system
console interface. It is recommended that you save your configuration
frequently, after you configure each module, and then again after
configuring the connections of each type you will have in your system.
Finally, before you exit your current session, be sure you save your
configuration for the last time by performing the steps in the following
procedure.
!
CAUTION:
If your system or location loses power or your current session ends
abnormally while you are in the process of configuring the system, and
you have not yet saved the values permanently, you will lose all unsaved
values you have applied on the various windows.
Saving the PSAX System Values
Begin
1 Press Ctrl+G while on any window to display the Console Interface
Main Menu window.