Creating Connections
®
1-Port Channelized STS-1e, T1 Format Module User Guide, Issue 1
PacketStar
255-700-184
Chapter 8 Provisioning Connections Using the AQueView
Figure 8-13. Delete AAL2 Trunk Config Entry Confirmation Window
b. Do one of the following:
~ Double-click the entry you want to delete.
~ Click the entry you want to delete, and select Display from the right
mouse menu.
The VIEW AAL2 Trunk Config Entry window appears.
3 Click Delete.
A confirmation window appears (see Figure 8-13).
4 Click Yes.
The AAL2 trunk entry is removed from the AAL2 Trunk Configuration
Table. Proceed to Step 5.
5 Click Close.
6 In the Provisioning Menu Bar, click Device > Save PSAX
Configuration.
End
This section provides instructions on how to create connections and describes
the errors that can occur when you are creating them.
If an error occurs while creating a connection, the AQueView system displays
an error message. There are many causes for these errors, but the errors that
occur the most frequently are described below:
•
Using an out-of-range VPI, VCI, or DCLI
•
Selecting an interface that does not support flow settings that are entered
•
Selecting out-of-range transmission parameters
•
Attempting to create a connection on an unconfigured interface or an
interface that has never been brought into service
•
Exceeding the maximum bandwidth available for a VBR and CBR
connection
®
System
Creating Connections
Release 7.0
8-21